SurgeX SX20NERT Surge Eliminator & Power Conditioner 20A at 120 Volts

SurgeX SX20NERT Surge Eliminator & Power Conditioner 20A at 120 Volts

  • $599.00
    Unit price per 


SurgeX SX20NERT Surge Eliminator & Power Conditioner - 20 Amps at 120 Volts

The SurgeX SX20 NE/RT has remote control capability for use in AC power distribution systems and can be interfaced with a sequential controller such as the SurgeX SEQ.

The unit can be controlled with an applied voltage (5-30 vdc) or a contact closure switch connected to the Phoenix connector terminal block. The connector can also be used to cascade multiple units or provide status to a central controller.

The SX20 NE/RT provides guaranteed surge protection and power conditioning for audio, video, broadcast and computer equipment. The units are 20-amp load-capable, 12" x 12" x 4" NEMA enclosures and meet code for use at the service entrance, sub-panels and in ceiling plenums.

The unit features both common mode and normal mode Impedance Tolerant EMI/RFI filtering as well as SurgeX ICE -Inrush Current Elimination for a comprehensive power conditioning solution.

SurgeX Advanced Series Mode technology is superior to conventional MOV circuitry or MOV-Hybrid designs and is completely non-sacrificial. Our zero let-through technology provides the most reliable protection available. It stops all surges up to 6,000 volts (unlimited surge current) without producing harmful side effects such as ground contamination or common-mode disturbances.

SurgeX SX20NERT Features:
  • Magnetic shielding steel enclosure
  • Advanced Series Mode surge protection
  • Advanced Impedance Tolerant EMI/RFI filtering
  • SurgeX ICE inrush current elimination technology
  • Remote turn-on
  • Self-test circuit with visual indicator
  • 10-year warranty
  • Made in U.S.A.

SurgeX SX20NERT Specifications:
  • Load Rating: 20 amps @ 120 volts
  • Power Requirement (no load): 15 watts
  • Surge Let-Through Voltage (6000-volt surge): 0 volts
  • UL 1449 Adjunct Classification Test Results:
    1000 surges, 6000 volts, 3000 amps, B3 pulse;
    Measured suppressed voltage: 170 volts; no failures.
  • Federal Guidelines: Grade A, Class 1, Mode 1
    (CID A-A-55818).
  • EMI/RFI Filter, Normal Mode (50-ohm load):
    40 dB @ 100 kHz; 50 dB @ 300 kHz;
    50 dB @ 3 MHz; 50 dB @ 30 MHz
  • EMI/RFI Filter, Common Mode (50-ohm load):
    18 dB @ 300 kHz; 30 dB @ 1 MHz;
    50 dB @ 5 MHz; 50 dB @ 20 MHz
  • Maximum Applied Surge Voltage: 6000 volts.*
  • Maximum Applied Surge Current:
    Unlimited, due to current limiting.*
  • Maximum Applied Surge Energy:
    Unlimited, due to current limiting.*
  • Endurance (C62.41-1991 Category B3 pulses):
    1 kV>500,000; 3 kV>10,000; 6 kV>1000
  • Maximum Load Inrush Current During Power-up: 1000 Joules
  • Remote Turn-on Applied Voltage Range: 5 to 30 volts DC
  • Remote Turn-on Current Draw:
    Contact Closure: 3 mA
    5 V DC Applied Voltage: 1 mA
    12 V DC Applied Voltage: 2.5 mA
    24 V DC Applied Voltage: 5 mA
  • Auxiliary Relay Contact Rating: 30 Volts at 1 Amp
  • LED Output: 12 volts DC, maximum 20 mA (resistor required)
  • Dimensions: 12.0" H x 12.0" W x 4.0" D (30.5 x 30.5 x 10.2 cm)
  • Weight: 12 lbs (5.45 kg)
  • Temperature Range: 5? to 35? C
  • Humidity Range: 5% to 95% R.H., non-condensing
  • Agency Listings: ETL and cETL (UL 1449, 2nd edition;
    CSA C22.2 No.8-M1986, R2000)

*1.2 x 50 ?pulse, industry standard combination wave surge, as per IEEE C62.41